Please use this identifier to cite or link to this item:
http://riu.ufam.edu.br/handle/prefix/9978| metadata.dc.type: | Trabalho de Conclusão de Curso |
| Title: | Comparação de métodos de cálculo de redes de esgotamento sanitário: estudo de caso |
| metadata.dc.creator: | Gonçalves, Enzo Gabriel Souza |
| metadata.dc.contributor.advisor1: | Contente, Ellem Cristiane Morais de Souza |
| metadata.dc.contributor.referee1: | Souza, Paulo Rodrigues de |
| metadata.dc.contributor.referee2: | Silva, Maria de Nazaré Alves da |
| metadata.dc.description.resumo: | O esgotamento sanitário constitui um componente essencial do saneamento básico, sendo responsável pela coleta, pelo transporte e pelo encaminhamento adequado dos esgotos sanitários até as unidades de tratamento ou disposição final. O desempenho hidráulico das redes coletoras depende da correta definição dos parâmetros de projeto, das condições topográficas e dos procedimentos adotados para o dimensionamento. Nesse contexto, este trabalho teve como objetivo comparar dois métodos de dimensionamento hidráulico de redes coletoras de esgoto sanitário, aplicando-os a uma rede projetada para um recorte da Comunidade Ismail Aziz, em Manaus (AM), a fim de avaliar seu desempenho quanto aos parâmetros hidráulicos, à conformidade com os critérios normativos e às implicações técnicas decorrentes de sua aplicação. Para garantir a comparabilidade entre os métodos, ambos foram aplicados às mesmas condições de projeto, mantendo-se inalterados o traçado, os diâmetros, as declividades e os demais parâmetros de dimensionamento. Os resultados demonstraram que os dois métodos apresentaram desempenho equivalente quanto à relação entre a lâmina d'água e o diâmetro da tubulação (Y/D), à velocidade de escoamento e à definição dos diâmetros comerciais, atendendo integralmente aos critérios estabelecidos pela ABNT NBR 9649 para essas variáveis. As diferenças observadas concentraram-se na avaliação da tensão trativa, parâmetro diretamente relacionado às condições de autolimpeza da rede, evidenciando maior sensibilidade do Método 2 para identificar situações hidráulicas próximas aos limites normativos. Conclui-se que a utilização de uma formulação contínua para determinação da relação Y/D preserva a consistência dos resultados hidráulicos do dimensionamento convencional, ao mesmo tempo em que amplia a confiabilidade da verificação das condições de autolimpeza em situações hidráulicas críticas, constituindo uma alternativa tecnicamente consistente para apoiar o dimensionamento de redes coletoras de esgoto sanitário. |
| Abstract: | Sanitary sewer systems are an essential component of basic sanitation, being responsible for the collection, conveyance, and proper disposal of wastewater generated in urban areas. The hydraulic performance of sewer networks depends on the appropriate definition of design parameters, topographic conditions, and the calculation procedures adopted during the design process. In this context, this study compared two hydraulic design methods for sanitary sewer networks by applying them to a sewer system designed for a selected area within the Ismail Aziz Community, located in Manaus, Amazonas, Brazil. The comparison aimed to evaluate their performance regarding hydraulic parameters, compliance with design standards, and the technical implications of their application in engineering projects. To ensure a consistent comparison, both methods were applied under identical design conditions, maintaining the same network layout, pipe diameters, slopes, design flows, and other hydraulic parameters. The results showed that both methods produced equivalent hydraulic designs with respect to the depth-to-diameter ratio (Y/D), flow velocity, and pipe diameter selection, fully complying with the requirements established by the Brazilian standard ABNT NBR 9649 for these variables. The differences were concentrated in the evaluation of shear stress, the parameter directly associated with the self-cleansing conditions of the sewer network. The second method demonstrated greater sensitivity in identifying hydraulically critical conditions operating close to the minimum design limits established by the standard. It is concluded that the use of a continuous analytical formulation for determining the depth-to-diameter ratio preserves the hydraulic consistency of conventional sewer design while improving the reliability of self-cleansing verification under critical hydraulic conditions, representing a technically consistent alternative for supporting the hydraulic design of sanitary sewer networks. |
| Keywords: | Esgotamento sanitário Redes coletoras Dimensionamento Métodos de cálculo Análise comparativa |
| metadata.dc.subject.cnpq: | ENGENHARIAS: ENGENHARIA CIVIL |
| metadata.dc.language: | por |
| metadata.dc.publisher.country: | Brasil |
| metadata.dc.publisher.department: | FT - Faculdade de Tecnologia |
| metadata.dc.publisher.course: | Engenharia Civil - Bacharelado - Manaus |
| metadata.dc.rights: | Acesso Aberto |
| metadata.dc.rights.uri: | https://creativecommons.org/licenses/by-nc-nd/4.0/ |
| URI: | http://riu.ufam.edu.br/handle/prefix/9978 |
| Appears in Collections: | Trabalho de Conclusão de Curso - Graduação - Engenharias |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| TCC_EnzoGonçalves.pdf | 2,05 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.