Resumo (Portuguese)
Este trabalho apresenta o estudo eletroquímico do processo de oxirredução do fungicida
Oxicloreto de cobre utilizado em cultivos da Vila do Engenho em Itacoatiara – AM. O estudo
busca quantificar esse fungicida em formulação padrão e comercial utilizando a técnica de
voltametria cíclica sobre a superfície eletródica do eletrodo de carbono vítreo em tampão
Britton-Robinson como eletrólito suporte. As análises foram realizadas variando o pH do
eletrólito entre 2 e 12; estudando janelas de potencial entre -1,0 a +1,0 V e -0,6 a +0,8 V; a
velocidade de varredura nos intervalos de 5 a 500 mV/s e verificando os limites de detecção e
quantificação. A metodologia desenvolvida foi aplicada em amostras de frutos e verduras
cultivadas com o uso desse agrotóxico. Os resultados mostraram viabilidade da técnica no
estudo do Oxicloreto de cobre e boa repetitividade. Nas amostras coletadas não foram
encontrados traços desse fungicida sugerindo-se que sua possível presença estivesse em
concentrações abaixo do limite de detecção da técnica.
Abstract
This work presents the study of electrochemical redox process fungicide copper oxychloride
used in crops of Mill Village in Itacoatiara - AM. The study seeks to quantify this fungicide in
standard formulation and commercial using cyclic voltammetry technique on the electrode
surface of the glassy carbon electrode in Britton-Robinson buffer as supporting electrolyte. The
analyzes were performed by varying the pH of the electrolyte between 2 and 12; windows
studying potential between -1,0 and -0,6 V to +1.0 V to +0,8 V; Scan speed in between 5-500
mV / s and checking the limits of detection and quantification. The methodology was applied
to samples of fruits and vegetables grown with the use of this pesticide. The results showed
technical feasibility copper oxychloride study and good repeatability. The samples were not
found traces of this fungicide suggesting that his presence was possible at concentrations below
the limit of detection technique.
Description
Keywords
Controlled term
Estudo eletroquímico; Oxicloreto de cobre; Eletrodo de carbono vítreo; Voltametria cíclica
Sustainable Development Goals (SDG)
Citation
SOUZA, Fênix Rafaiela Fernandes. Eletrodo de carbono vítreo aplicado na determinação de fungicida oxicloreto de cobre utilizado por agricultores da Vila do Engenho - AM. 2016. 67 f. Dissertação (Mestrado em Ciência e Tecnologia para Recursos Amazônicos) - Universidade Federal do Amazonas, Itacoatiara, 2016.