Avaliação do impacto da implementação do método de revisão aleatória de 10% das amostras negativas na garantia da qualidade dos exames citopatológicos realizados no laboratório municipal em Manaus-AM
Loading...
Date
Authors
Advisor(s)
Co-advisor(s)
Committee members
Rondon, Heidy Halanna de Melo Farah
Morais, Márcia Poinho Encarnação de
Morais, Márcia Poinho Encarnação de
Graduate program
Journal Title
Journal ISSN
Volume Title
Publisher
Universidade Federal do Amazonas
Type
Access rights
DOI
Resumo (Portuguese)
Programas de controle de qualidade em citopatologia são necessários para
avaliar o desempenho laboratorial com a finalidade de minimizar falhas e
providenciar correções, assegurando a eficácia laboratorial no programa de
rastreamento do câncer de colo do útero pelo exame preventivo. Este trabalho
avaliou o impacto da implementação do método de revisão aleatória de 10% das
amostras negativas na melhoria da qualidade dos exames em um laboratório em
Manaus – AM. Trata-se de um estudo descritivo, retrospectivo e quantitativo que
comparou os indicadores de qualidade do Laboratório Municipal de
Especialidades Professor Sebastião Ferreira Marinho, antes e após a
restruturação do método de Revisão aleatória de 10% das amostras negativas
(antes de 2018 e após 2018) entre o período de 2007 a 2021. O estudo mostrou
que a taxa de mortalidade por câncer de colo do útero apresentou estabilização
ao longo dos anos, de 12,18% em 2007 para 15,79% em 2021, apesar de picos
temporários, como em 2013 e 2014. A maioria dos resultados dos indicadores da
qualidade encontrados, permaneceram dentro dos padrões da literatura, embora
tenham ocorridos variações ao longo dos anos. No início, entre 2007 e 2010 o
índice de positividade (IP) apresentava resultados abaixo do preconizado,
variando de 1,1 a 1,7. De 2011 a 2021 manteve-se dentro do esperado, iniciando
um aumento em 2011, 2,8 permanecendo entre 2,5 e 4,9 entre 2012 a 2021. Não
houve discordância significativa entre os citologistas da rotina e os revisores do
monitoramento interno de qualidade (MIQ), com a maior parte das discordâncias
concentrada nas categorias ASC-US e LSIL. Não houve discordância
significativa entre os turnos de trabalho dos citologistas no período da manhã e
tarde. A perspectiva fundamentou-se em medidas destinadas a detectar, corrigir
e reduzir deficiências do processo de produção dentro do laboratório,
proporcionando com isso o aperfeiçoamento dos procedimentos e minimizando
as ocorrências de erros de diagnósticos.
Abstract
Quality control programs in cytopathology are essential for evaluating laboratory
performance to minimize errors and implement corrective actions, thereby
ensuring efficacy in cervical cancer screening through preventive examinations.
This study assessed the impact of implementing of the random review method of
10% of negative samples on the quality improvement measures in a laboratory in
Manaus, Amazonas, Brazil. It is a descriptive, retrospective, and quantitative
study that compared the quality indicators of the Professor Sebastião Ferreira
Marinho Municipal Specialty Laboratory before and after restructuring the method
of random review of 10% of negative samples (pre-2018 and post-2018) over the
period from 2007 to 2021. The study revealed that the mortality rate from cervical
cancer stabilized over the years, from 12.18 % per 100,000 women in 2007 to
15.79% in 2021, despite temporary peaks in 2013 and 2014. Most of the results
of the quality indicators found remained within the standards of the literature,
although there have been variations occurred over the years. Initially, between
2007 and 2010, the Positivity Index (PI) showed results below the recommended
levels, ranging from 1.1 to 1.7. From 2011 to 2021, it remained within the
expected range, starting to increase in 2011 (2.8) and fluctuating between 2.5
and 4.9 from 2012 to 2021. There was no significant disagreement between
routine cytologists and Internal Quality Monitoring (IQM) reviewers, with most
discrepancies concentrated in the categories of ASC-US (Atypical Squamous
Cells of Undetermined Significance) and LSIL (Low-grade Squamous
Intraepithelial Lesion). No significant disagreement was observed between the
morning and afternoon work shifts of the cytologists. These findings underscore
the importance of implementing measures aimed at detecting, correcting, and
reducing deficiencies in laboratory processes, thereby enhancing procedures and
minimizing diagnostic errors.
Description
Controlled term
Papanicolaou, Teste de; Câncer - Citodiagnóstico
Sustainable Development Goals (SDG)
Citation
REFFERRT, Rita de Cássia Alencar. Avaliação do impacto da implementação do método de revisão aleatória de 10% das amostras negativas na garantia da qualidade dos exames citopatológicos realizados no laboratório municipal em Manaus-AM. 2024. 76 f. Dissertação (Mestrado em Ciências Farmacêuticas) - Universidade Federal do Amazonas, Manaus (AM), 2024.
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwise noted, this item's license is described as Acesso Aberto